Export each DOORS module with a stable identifier on every object (the absolute number), export the links keyed by that same identifier, and import them into the new tool so that each link resolves to an object, not to a position. Then verify link counts per link type, not just object counts, before you freeze DOORS and keep the old baselines read-only as the archive. ReqIF carries the most structure, CSV carries the least, and whichever route you pick, a pilot on one real module will show you what your data loses.
What can you export from DOORS?
There are four practical routes. IBM documents the first and third; the second is whatever you or your tool vendor build.
ReqIF. DOORS 9.4 and later export ReqIF (versions 1.0, 1.1 and 1.2 are supported), and DOORS also supports the older RIF format. ReqIF is an XML exchange format governed by the Object Management Group. In DOORS you define a ReqIF definition on the project's properties and export it as a package. IBM's documentation says you need permission to partition data and modify access to the project, the project and modules in the definition must not be open, and data locks are applied as the definition prescribes.
DXL or a custom XML export. DXL is DOORS's scripting language, and IBM lists integration with other tools among its uses. I did not find an IBM page that documents a standard "DOORS XML" export file. In practice, the "DOORS XML" you hold is whatever your script or vendor tool wrote, so you must know its layout.
CSV or Excel. DOORS can export the current view, or selected attributes, to a CSV or TSV file that Excel can open. IBM says the exporter writes one line per object.
Word, PDF, HTML. IBM documents document generation to those formats. They are reading copies for review packs and are not a migration route.
What does each export route lose?
IBM's documentation, plus my own reading of what a flat file cannot hold:
| Route | What it carries | What it loses or what to check |
|---|---|---|
| ReqIF | Hierarchy, attributes, links, public views. IBM's DOORS Next importer reads attribute definitions, data types, folders, links, link types, modules and artifact types from ReqIF. | A link from a DOORS package appears only when both endpoints are in the package, so exporting module by module drops cross-module links. DOORS has an optional "Export baseline information" setting. Importing tools may not read everything: DOORS Next cannot import comments, reviews or audit histories from ReqIF. |
| DXL or custom XML | Whatever the script writes: usually objects, attributes, text and links. | Only what the script author thought of. Check link modules, link types, rich text and baselines explicitly. |
| CSV or Excel | Attribute values per object, in the columns you choose. | IBM states rich text formatting and special characters are not preserved. A flat file has no native place for typed links, so you need extra columns or a second extract. A flat text file cannot hold OLE objects or pictures. |
| RTF export | Formatted text; IBM says OLE objects are included but pictures are not. | A reading copy, not a data transfer. |
IBM's own migration guidance for moving DOORS to DOORS Next is a useful checklist of what usually does not move. It says to convert Layout DXL to Attribute DXL because Layout DXL migration is not supported, to simplify complex tables first, and it notes that history, baselines and discussions are not included in the migration. IBM's answer is to leave the original data in DOORS as a historical archive, and the migration process then creates links to it. That pattern is the right one for any tool.
How do you keep link identity when you move?
A link says "object A relates to object B". If A and B change identity during the move, the link breaks even though both objects arrived. Three rules prevent it.
1. Use the absolute number as the key. IBM's documentation says each DOORS object has a unique absolute number, and once assigned that number is never used again, even if the module is closed without saving the new object. Heading numbers describe position, so they change when someone inserts a section. Export the absolute number (or your prefix plus absolute number) on every object and use it as the endpoint in every link.
2. Write links by key, not by row or heading. In whichever format you use, the link must name its source and target by that key. A link file that says "section 3.2.1 to section 7.4" will not survive a re-sort.
3. Carry the old identifier into the new tool as data. Do not rely on the new tool's numbering to match. Keep the DOORS identifier as an attribute (for example "Legacy ID"). Reviewers, test procedures and design documents that cite the old ID will need to find the object for years after cutover.
Also decide what happens to links that point out of scope. If module A links to a module B that you migrate later, the first import will skip or dangle those links. Migrate linked modules together, or use a tool that resolves endpoints against earlier imports.
What is a safe migration plan?
This is the sequence I use.
- Inventory. List every module, its object count, its attributes (name, type, enumeration values), its link modules and link types, its baselines and any OLE or picture content. IBM ships a Migration Metrics utility in DOORS that reports the number of objects, links, OLE objects and attributes, which also helps for any target. Remove attributes with no business value and harmonize enumerations that differ only in case or wording.
- Pilot. Pick one real module with links to a test module and a parent module. Export it, import it into the target, and look at it with the engineer who owns it.
- Map attributes and link types. Decide, per DOORS attribute, the target attribute and type. Decide, per DOORS link module or link type, the target link type. Write the mapping down for the audit.
- Import. Run the full import for the modules in scope, in an order that keeps linked modules together, or in a tool that resolves earlier imports.
- Verify counts and links. Compare object counts per module, link counts per link type, and the list of links skipped or dropped. Spot-check ten objects and ten links by hand. Run the same trace-coverage question in both tools ("which requirements have no verifying test?") and compare the lists. See the bidirectional traceability audit for the evidence an auditor will want.
- Freeze. Agree a date after which nobody edits in DOORS. If work has to continue meanwhile, plan a delta re-import (see below) before the freeze.
- Cutover. Run the final import from the frozen DOORS data, verify again, and tell the team the target is the source of truth.
- Keep the old baseline read-only. Leave the DOORS database available as an archive, with access reduced to read. IBM's process does the same: the original data stays in DOORS as a historical archive for history and baselines that did not migrate.
How does NexusRM import DOORS data and keep the traces?
NexusRM has importers for DOORS XML, Jama CSV and Jama XML, plus its own CSV and XML export format. It does not import ReqIF. Here is exactly what the DOORS XML importer does, from the product's code and pages. The import and export page gives the summary.
It validates before it commits. An upload is parsed and checked first, producing a validation report with warnings and errors (for example, a missing ID or title, a link with a missing endpoint, duplicate source IDs). Nothing in the project changes until a project administrator confirms. The commit is atomic: all or nothing. Uploads are limited to 50 MB per file.
It reads a defined DOORS XML profile. The importer expects a root element, nested module elements, requirement elements with an ID, a title, text and attributes, and link elements with a source, a target and a type. In outline:
<dof>
<module name="Avionics">
<req id="1042">
<title>Altitude hold</title>
<text>The FMS shall hold altitude within the commanded band.</text>
<attribute-set>
<attribute name="Priority"><value>High</value></attribute>
</attribute-set>
</req>
<link source="2210" target="1042" type="Verifies"/>
</module>
<baseline name="CDR"/>
</dof>
The parser is deliberately tolerant and reports structural variants as validation issues. Real exports vary across DOORS versions and scripts, so the honest answer to "will my file import?" is: send us a sample from your database and we will check it against the profile. If your only export is ReqIF, you need a conversion step into this layout first.
It keeps link identity through the source ID. The id of each requirement is stored as the object's source ID. Links are resolved through source IDs, including those of items imported in earlier runs, so you can import modules in stages. Re-importing a file matches items by source ID: existing items are updated, new IDs are inserted, and deleting items that disappeared from the source is an explicit option that defaults to off. If the same ID appears twice in one file, the report lists it and you choose how to resolve each one. NexusRM assigns its own object numbers from each module's prefix, so create a "Legacy ID" attribute definition beforehand and include the DOORS absolute number as an attribute in the file. Attributes without a matching definition or mapping are dropped and counted, not silently kept.
It treats links carefully. The default link types are Decomposes, Verifies and Impacts, and administrators can add project-specific link types. A link with no type becomes Impacts. A link whose type NexusRM does not know is skipped and counted, not invented, so add the link types you need before importing. Links with a missing endpoint, links from an object to itself and duplicate links are also skipped and counted, and the commit reports links created and links skipped, which is the number to compare with your DOORS link count. See Traceability for how links work afterwards.
What it does not carry over. Be clear about these before promising anyone a lossless move:
- Hierarchy inside a module. The DOORS profile maps the module tree and preserves document order, but does not rebuild heading-level nesting inside a module. Check this in the pilot.
- Rich text. RTF is converted to plain-text paragraphs. Formatting is lost, and pictures and OLE objects are not carried. Plan to keep those in the archive or reattach them as needed.
- History and baseline content. A baseline name in the file creates a baseline in each module the import touched, described as created by the import. The importer reads only the name, so it does not reconstruct the content of an old DOORS baseline, and DOORS version history is not imported. This is why step 8 keeps the DOORS archive.
- ReqIF. Not supported today.
After the move. Each import is recorded as a job with its report and counts, and the commit is written to the audit log. NexusRM can export a whole project to its documented CSV or XML format, and re-importing that export reproduces the project, so the data is not locked in either. See Baselines for freezing your first review in the new tool. If you are comparing tools first, read alternatives to IBM DOORS for an air-gapped program.
Frequently asked questions
Can I export from DOORS to ReqIF and keep my links?
Yes, with a condition. IBM says a package exported from DOORS contains a link only when both endpoints are in the package, so cross-module links disappear if you export modules separately. Put linked modules in one ReqIF definition, and check link counts after import.
What is the absolute number in DOORS, and why does it matter?
It is the unique number DOORS gives each object when it is created. IBM says it is never reused once assigned. Because heading numbers change when sections move, the absolute number is the only stable key for matching objects and link endpoints across an export and import.
Does CSV or Excel export keep traceability?
Not by itself. IBM's spreadsheet export writes one line per object with the attributes you choose, and does not preserve rich text formatting. Typed links need to come out in additional columns or a separate extract, and you must keep the object identifier in both.
Does NexusRM import ReqIF?
No. NexusRM imports DOORS XML (a defined profile), Jama CSV and Jama XML, and its own XML export. If your DOORS data is only available as ReqIF, it needs converting to the DOORS XML layout first. Send us a sample export and we will tell you what is needed.
How do I know the migration did not lose links?
Compare numbers per link type before and after, review the list of skipped links, and run the same coverage question in both tools. In NexusRM the commit reports links created and links skipped. A skipped count above zero is not necessarily wrong, but each one needs an explanation.
Sources
- IBM: Exporting ReqIF packages in DOORS
- IBM: RIF and ReqIF in DOORS
- IBM: Importing ReqIF files into DOORS Next
- IBM: Migration process phases (DOORS to DOORS Next)
- IBM: Exporting to spreadsheet in DOORS
- IBM: Exporting data from formal modules (DOORS 9.7.0)
- IBM: Exporting to RTF (DOORS 9.7.0)
- IBM: Creating objects in DOORS (absolute numbers)
- IBM: Comparison of DOORS and DOORS Next (DXL)
- OMG: Requirements Interchange Format (ReqIF) 1.2
- NexusRM import and export, traceability and baselines, and the NexusRM overview